A DUST COLLECTOR THAT GROWS WITH YOUR BUSINESS
Details
UPGRADABLE BLOWER
The BELFAB open dust collector modular series comes with our patented upgradable blower, that makes it possible to increase blower performance (on our standard blower) from a 5HP/2500CFM to a 20HP/ 6000 CFM MAX by simply replacing motor and impeller within the same fan housing.
Our optional HUMMER 1800 RPM fan offers super quiet operation at up to 9000 CFM* (see note). In applications where there is a requirement for low sound level (under 84 db), BELFAB HUMMER series is available for application ranging from 10HP to 20HP 5000 CFM.
*up to 5000CFM for indoor installation. Above 5,000 CFM an outdoor set up is required (NFPA 664)
FEATURES
- Vertical mechanical manual shaker cleaning system
- Low maintenance direct drive centrifugal fan
- High efficiency TEFC motor, CSA-UL or CSA-US approved
- High efficiency needle felt filter bags
- The unit is configured for push application only
OPTIONS
- Extended legs for maximum dust disposal (height increased by 2 feet)
- Easy access under the dust collector
- Silencer for standard blower configuration
- Pre-wired magnetic starter
FILTER MODULES ARRANGEMENTS
Number of filter modules | 1 | 2 | 3 | 4 | 5 | 6 |
Filtration surface (sq.ft.) | 165 | 330 | 495 | 660 | 825 | 990 |
Dimension (W x D X H) in. | 48” x 48” x 130” | 72” x 48” x 130” | 96” x 48” x 130” | 120” x 48” x 130” | 144” x 48” x 130” | 168” x 48” x 130” |
Module weight (lbs) | 250 | 500 | 750 | 1 000 | 1 250 | 1 500 |
( Note: When equipped with a hummer blower module, add 18” to width)
STANDARD BLOWER – 3600RPM | HUMMER BLOWER – 1800 RPM | |||||||
FAN MODULE | 5HP | 7.5HP | 10HP | 15HP | 20HP | 10HP | 15HP | 20HP |
Capacity (CFM) | 2 500 | 3 500 | 4 600 | 5 000 | 6 000 | 4 600 | 5 000 | 6 000 |
Recommended number of filter modules | 1 to 3 | 2 to 4 | 2 to 5 | 3 to 6 | 4 to 6 | 3 to 6 | 4 to 6 | 4 to 6 |
Sound pressure (dB) at 10´ (without a silencer) | 82 | 84 | 88 | 92 | 92 | 80 | 81 | 83 |
Inlet diameter (in.) | 9 | 10 | 12 | 14 | 16 | 12 | 14 | 16 |
Module weight (lbs) | 200 | 240 | 250 | 340 | 360 | 350 | 450 | 560 |
NUMBER OF FILTER MODULES REQUIRED : GUIDELINES
BLOWER | LIGHT USAGE (under 3 hours a day) | MEDIUM USAGE (3 to 6 hours a day) | HEAVY USAGE (more than 6 hours a day) | ||||||
HP | Coarse | Mixed | Fine | Coarse | Mixed | Fine | Coarse | Mixed | Fine |
5HP | 2 | 2 | 2 | 2 | 2 | 2 to 3 | 2 to 3 | 3 | 3 |
7.5HP | 2 | 2 | 2 | 2 | 2 to 3 | 3 | 3 | 3 to 4 | 4 |
10HP | 3 | 3 | 3 | 3 | 3 to 4 | 4 | 4 to 5 | 4 to 5 | 4 to 5 |
15HP | 3 | 3 | 3 | 3 to 4 | 4 | 4 to 5 | 5 | 5 to 6 | 6 |
20HP | 4 | 4 | 4 | 4 | 4 | 4 to 4 | 4 to 5 | 5 to 6 | 5 to 6 |